DNV Type Approval Certificate TAE000050B for Anhui Tiankang XLPE insulated shipboard power cables type CJPF86/SC, CJPF96/SC, CJPJ85/SC, CJPJ95/SC, 0.6/1kV, flame retardant, halogen free and low smoke.
If the download does not open, please contact sales@tiankangmail.com for a verified copy.
DNV Type Approval Certificate TAE000050B

Certificate Overview
This page provides the DNV Type Approval Certificate TAE000050B issued to Anhui Tiankang (Group) Shares Co., Ltd. for XLPE insulated shipboard power cables with type designation CJPF86/SC, CJPF96/SC, CJPJ85/SC and CJPJ95/SC.
Certificate number: TAE000050B
Rated voltage: 0.6/1kV
Temperature class: 90°C
Issued: 2025-01-07 at Hamburg
Valid until: 2030-01-06
Issued by: DNV
DNV Job ID: 262.1-040955-1
The certificate confirms that the cable type complies with DNV rules for classification of ships, offshore units and high speed and light craft. Products covered by this certificate are accepted for installation on vessels classed by DNV, subject to the certificate terms and project requirements.
Approved Cable Types
CJPF86/SC
CJPF96/SC
CJPJ85/SC
CJPJ95/SC
These are XLPE insulated shipboard power cables designed for marine power, lighting and control applications where flame retardant, halogen free and low smoke performance is required.
Cable Construction
Conductor: tinned stranded copper, class 2
Insulation: XLPE
Inner sheath: PF type SHF1, PJ type SHF2
Armour / braid options: copper wire braid, or galvanized steel wire braid, not for single core cable
Outer sheath: SHF1 or SHF2 material depending on type
The certificate covers a wide range of core numbers and cross sections, including 1x1.0, 1x1.5, 1x2.5, 1x4, 1x6, 1x10, 1x16, 1x25, 1x35, 1x50, 1x70, 1x95, 1x120, 1x150, 1x185, 2x1.0, 2x1.5, 2x2.5, 2x4, 2x6, 2x10, 2x16, 2x25, 2x35, 2x50, 2x70, 2x95, 2x120, 2x150, 2x185, 3x1.0, 3x1.5, 3x2.5, 3x4, 3x6, 3x10, 3x16, 3x25, 3x35, 3x50, 3x70, 3x95, 3x120, 3x150, 3x185, 4x1.0, 4x1.5, 4x2.5, 5x1.0, 5x1.5, 5x2.5, 7x1.0, 7x1.5, 7x2.5, 8x1.0, 8x1.5, 8x2.5, 10x1.0, 10x1.5, 10x2.5, 12x1.0, 12x1.5, 12x2.5, 14x1.0, 14x1.5, 14x2.5, 16x1.0, 16x1.5, 16x2.5, 19x1.0, 19x1.5, 19x2.5, 24x1.0, 24x1.5, 24x2.5, 27x1.0, 27x1.5, 27x2.5, 30x1.0, 30x1.5, 30x2.5, 37x1.0, 37x1.5 and 37x2.5.
Flame and Material Performance
According to the type approval documentation, the cable is flame retardant Category A, halogen free and low smoke. The certificate lists compliance with the following main test standards:
IEC 60092-350: general construction and test methods of power, control and instrumentation cables for shipboard and offshore applications
IEC 60092-353: power cables for rated voltages 1kV and 3kV
IEC 60092-360: insulating and sheathing materials for shipboard and offshore cables
IEC 60332-3-22: vertical flame spread of vertically mounted bunched wires or cables, Category A
IEC 60754-1: halogen acid gas content, low halogen
IEC 60754-2: acidity and conductivity, halogen free
IEC 60684-2 clause 45.2: low level fluorine content
IEC 61034-1/2: smoke density, light transmittance greater than 60%
Application
This certificate applies to XLPE insulated shipboard power cables used for general power, lighting and control systems on ships and offshore units where DNV type approved cable is required. Typical project areas include ship power distribution, lighting circuits, control circuits and general marine electrical systems.
Related Cable Pages
For the related marine cable range, see Marine & Offshore Cables. For the applicable shipboard power cable standard guide, see IEC 60092-353 Shipboard Power Cable Guide. To confirm project applicability, certificate scope or TDS, please contact Anhui Tiankang.
Certificate Download and Verification
Use the Download button on this page to get the DNV certificate PDF. For project submission, please confirm the cable type, size, standard and certificate validity with the Anhui Tiankang sales team before order placement. The certificate validity date relates to the type approval certificate and not to the approval of equipment or systems installed.
FAQ
Q1: Which cable types are covered by DNV certificate TAE000050B?
The certificate covers CJPF86/SC, CJPF96/SC, CJPJ85/SC and CJPJ95/SC XLPE insulated shipboard power cables.
Q2: What is the rated voltage and temperature class?
The rated voltage is 0.6/1kV and the temperature class is 90°C.
Q3: Is this certificate still valid?
The certificate was issued on 2025-01-07 and is valid until 2030-01-06, subject to DNV terms and periodical assessment requirements.
Q4: What is the difference between TAE000050B and TAE000050C?
TAE000050B covers CJPF86/SC, CJPF96/SC, CJPJ85/SC and CJPJ95/SC with flame retardant, halogen free and low smoke performance. TAE000050C covers CJ85/NSC, CJ86/NSC, CJ95/NSC and CJ96/NSC with mica tape fire resistant performance. Please choose the certificate according to the required cable type.
Q5: Can I use this certificate for ship projects classed by other societies?
This document is a DNV type approval certificate. For CCS, ABS, LR, BV or RINA projects, please confirm the applicable certificate or test report with our sales team.
Request Verified Copy
For quotation, TDS, cable size confirmation or a verified certificate copy for project submission, please contact Anhui Tiankang with the cable type, standard, specification, quantity and destination port.