Nippon Kaiji Kyokai type test certificate TA24282M for Anhui Tiankang 0.6/1kV shipboard low voltage power cables, flame retardant, fire resistant, low smoke and halogen free types, valid until 19 June 2029.
If the download does not open, please contact sales@tiankangmail.com for a verified copy.
NK Type Test Certificate TA24282M

Certificate Overview
This page provides the Certificate of Type Test TA24282M issued by Nippon Kaiji Kyokai (NK) to Anhui Tiankang (Group) Shares Co., Ltd. for 0.6/1kV shipboard low voltage power cables.
Certificate No.: TA24282M
Type Test No.: 24T802
Product: 0.6/1kV shipboard low voltage power cables
Rated voltage: 0.6/1kV
Maximum conductor temperature: 90°C
Issued: 20 June 2024 at Tokyo
Valid until: 19 June 2029
Test reports: TN24-1612A1E, TK24-1613A1E
The certificate approves the above mentioned product in accordance with the Society's type test requirements for electrical equipment and cables. Cable type numbers, constructions and size ranges are listed in the attached sheet of the certificate.
Covered Cable Types
The attached sheet covers a wide range of shipboard low voltage power cable types with different insulation, sheath, armour and fire performance combinations, including:
CEF, CEFR, CEF80, CEF90 series with DA, SA, NA or NSA suffix
CEPF, CEPFR, CEPJR series with SC or NC suffix
CE86, CE85, CE95 series with SC or NC suffix
CEPF80, CEPF90, CEPJ85, CEPJ90 series
CJ86, CJ96, CJ85, CJ95, CJPJ, CJPJ80, CJPJ90 series with SC or NC suffix
CJPF, CJPF80, CJPF90, CJPJR, CJPFR series
Coverage includes 1 core, 2 core, 3 core, 4 core, 3+1 core and 5 core cables in sizes from 1mm2 up to 240mm2, and multi-core cables from 6 core to 37 core in sizes from 1mm2 to 4mm2. For the full type list, size range and construction details, please refer to the certificate attached sheet or contact Anhui Tiankang.
Type Designation Guide
The letters used in the cable type designations have the following meanings according to the certificate attached sheet:
C: shipboard power cable
J: XLPE insulation
E: EPR insulation
PJ: cross-linked polyolefin insulation or sheath
PF: thermoplastic polyolefin insulation or sheath
F: polychloroprene rubber sheath
SC: bunched cable flame retardant, low smoke and halogen free
NA(NSA): bunched cable flame retardant, fire resistance
NC(NSC): bunched cable flame retardant, fire resistance, low smoke and halogen free
DA: flame retardant type tested to IEC 60332-1-2
SA: flame retardant type tested to IEC 60332-1-2 and IEC 60332-3-22
8: copper wire or tinned copper wire braid
9: galvanized steel wire braid
5: cross-linked polyolefin outer sheath
6: thermoplastic polyolefin outer sheath
0: no outer sheath
Test Standards
The type test was carried out according to the following standards:
IEC 60092-350: general construction and test methods of power, control and instrumentation cables for shipboard and offshore applications
IEC 60092-353: power cables for rated voltages 1kV and 3kV
IEC 60092-360: insulating and sheathing materials for shipboard and offshore cables
IEC 60331-1: circuit integrity under fire conditions with shock, for cables up to 0.6/1.0kV
IEC 60332-1-2 and IEC 60332-3-22: flame retardant tests
IEC 60754-1 and IEC 60754-2: halogen acid gas content, acidity and conductivity
IEC 61034-1 and IEC 61034-2: smoke density under defined burning conditions
Application
This certificate applies to shipboard low voltage power cables used in marine power distribution systems on vessels and offshore units where NK related type tested cable is required. Depending on the type designation, the covered cables can be used for general power, lighting and control circuits with flame retardant, fire resistant, low smoke and halogen free performance.
Related Cable Pages
For the related marine cable range, see Marine & Offshore Cables. For the applicable shipboard power cable standard guide, see IEC 60092-353 Shipboard Power Cable Guide. To confirm type applicability, size coverage or project documentation, please contact Anhui Tiankang.
Certificate Download and Verification
Use the Download button on this page to get the NK certificate PDF with the attached type list sheet. Before order placement, please confirm the exact cable type designation, size range and certificate validity with the Anhui Tiankang sales team.
FAQ
Q1: What is certificate TA24282M?
TA24282M is a Nippon Kaiji Kyokai certificate of type test for Anhui Tiankang 0.6/1kV shipboard low voltage power cables, type test number 24T802.
Q2: When was this certificate issued and when does it expire?
The certificate was issued on 20 June 2024 and is valid until 19 June 2029.
Q3: Which sizes are covered?
The attached sheet covers 1 core to 5 core cables from 1mm2 to 240mm2, 3+1 core from 1mm2 to 185mm2, and 6 to 37 core cables from 1mm2 to 4mm2, subject to the listed type designations.
Q4: What do SC, NA and NC mean in the type designation?
SC means flame retardant, low smoke and halogen free. NA or NSA means flame retardant with fire resistance. NC or NSC means flame retardant, fire resistant, low smoke and halogen free.
Q5: Can one certificate cover both flame retardant and fire resistant types?
Yes. The attached sheet lists different type designations with different performance combinations. Please select the exact type designation according to the project requirement.
Request Verified Copy
For quotation, TDS, cable size confirmation or a verified certificate copy for project submission, please contact Anhui Tiankang with the cable type designation, standard, specification, quantity and destination port.