Certificate Overview
This page provides the Certificate of Type Test TA24283M issued by Nippon Kaiji Kyokai (NK) to Anhui Tiankang (Group) Shares Co., Ltd. for 150/250V(300V) shipboard control and instrumentation communication cables.
Certificate No.: TA24283M
Type Test No.: 24T803
Product: 150/250V(300V) shipboard control & instrumentation communication cables
Rated voltage: 150/250V(300V)
Maximum conductor temperature: 90°C
Issued: 20 June 2024 at Tokyo
Valid until: 19 June 2029
Test reports: TN24-1612A1E, TK24-1613A1E
The certificate approves the above mentioned product in accordance with the Society's type test requirements for electrical equipment and cables. Cable type numbers, pair configurations and size ranges are listed in the attached sheet of the certificate.
Covered Cable Types
The attached sheet covers shipboard control cables and shipboard communication and instrumentation cables with different insulation, shielding, armour and fire performance combinations, including:
CKEF, CKEF80, CKEF90 series with DA, SA, NA or NSA suffix
CKEPF, CKEPFP, CKEPJ, CKEPJR series with SC or NC suffix
CKE86, CKE96, CKE85, CKE95 series with SC or NC suffix
CKJ86, CKJ96, CKJ85, CKJ95, CKJP, CKJPF, CKJPFP series with SC or NC suffix
CHJPF, CHJPF80, CHJPFP, CHJFP86, CHJPJ, CHJPJ85, CHJPJ95 series with SC or NC suffix
CHJ85, CHJ96, CHJP85, CHJP96 series
Coverage includes 2 core to 48 core cables in conductor sizes from 0.5mm2 to 2.5mm2. Screened configurations are also covered, including 1P, 1T, 1Q and 2P to 37P designs. For the full type list and construction details, please refer to the certificate attached sheet or contact Anhui Tiankang.
Type Designation Guide
The letters used in the cable type designations have the following meanings according to the certificate attached sheet:
CK: shipboard control cable
CH: shipboard communication and instrumentation cable
J: XLPE insulation
E: EPR insulation
PJ: cross-linked polyolefin insulation or sheath
PF: thermoplastic polyolefin insulation or sheath
F: polychloroprene rubber sheath
DA: flame retardant type tested to IEC 60332-1-2
SA: flame retardant type tested to IEC 60332-1-2 and IEC 60332-3-22
NA(NSA): bunched cable flame retardant, fire resistance
NC(NSC): bunched cable flame retardant, fire resistance, low smoke and halogen free
SC: bunched cable flame retardant, low smoke and halogen free
P: pair to pair shielding, total shielding, or pair shielding plus total shielding, using tinned copper wire, copper wire or aluminum foil
8: copper wire or tinned copper wire braid
9: galvanized steel wire braid
5: cross-linked polyolefin outer sheath
6: thermoplastic polyolefin outer sheath
0: no outer sheath
Test Standards
The type test was carried out according to the following standards:
IEC 60092-350: general construction and test methods of power, control and instrumentation cables for shipboard and offshore applications
IEC 60092-376: control and instrumentation cables with rated voltage 150/250V
IEC 60092-360: insulating and sheathing materials for shipboard and offshore cables
IEC 60331-1: circuit integrity under fire conditions with shock, for cables up to 0.6/1.0kV
IEC 60332-1-2 and IEC 60332-3-22: flame retardant tests
IEC 60754-1 and IEC 60754-2: halogen acid gas content, acidity and conductivity
IEC 61034-1 and IEC 61034-2: smoke density under defined burning conditions
Application
This certificate applies to shipboard control and instrumentation communication cables used for control, signal, measurement and communication circuits on vessels and offshore units where NK related type tested cable is required. Screened types are suitable for circuits where interference control is needed.
Related Cable Pages
For the related marine cable range, see Marine & Offshore Cables. For the applicable control cable standard guide, see IEC 60092-376 Shipboard Control Cable Guide. To confirm type applicability, pair configuration or project documentation, please contact Anhui Tiankang.
Certificate Download and Verification
Use the Download button on this page to get the NK certificate PDF with the attached type list sheet. Before order placement, please confirm the exact cable type designation, core configuration, shielding structure and certificate validity with the Anhui Tiankang sales team.
FAQ
Q1: What is certificate TA24283M?
TA24283M is a Nippon Kaiji Kyokai certificate of type test for Anhui Tiankang 150/250V(300V) shipboard control and instrumentation communication cables, type test number 24T803.
Q2: When was this certificate issued and when does it expire?
The certificate was issued on 20 June 2024 and is valid until 19 June 2029.
Q3: What sizes and core configurations are covered?
The attached sheet covers 2 core to 48 core cables in sizes from 0.5mm2 to 2.5mm2, including screened pair configurations from 1P, 1T and 1Q up to 2P to 37P.
Q4: What is the difference between TA24282M and TA24283M?
TA24282M covers 0.6/1kV shipboard low voltage power cables. TA24283M covers 150/250V(300V) shipboard control and instrumentation communication cables. Please select the certificate according to the cable voltage level and application.
Q5: What does letter P mean in the type designation?
P means pair to pair shielding, total shielding, or pair shielding plus total shielding, using tinned copper wire, copper wire or aluminum foil.
Request Verified Copy
For quotation, TDS, cable type confirmation or a verified certificate copy for project submission, please contact Anhui Tiankang with the cable type designation, standard, specification, quantity and destination port.