Email: sales@tiankangmail.com Phone/WhatsApp: +86-18855014777 Request a Quote

ABS Product Design Assessment 21-2153557-PDA


ABS Product Design Assessment certificate 21-2153557-PDA for Anhui Tiankang CJ Series and CE Series XLPE/EPR insulated shipboard power cables, valid until 18 November 2026.

Download Certificate / Test Report

If the download does not open, please contact sales@tiankangmail.com for a verified copy.

ABS Product Design Assessment 21-2153557-PDA for CJ and CE series shipboard power cable

Certificate Overview

This page provides the ABS Product Design Assessment (PDA) certificate issued to Anhui Tiankang (Group) Shares Co., Ltd. by the American Bureau of Shipping, ABS Technical Office CN Shanghai.

  • Certificate number: 21-2153557-PDA

  • Product: Cable, Power

  • Model: CJ Series and CE Series shipboard power cables

  • Effective date: 19 November 2021

  • Expiration date: 18 November 2026

  • Manufacturer: No.20 South Renhe Road, Tianchang, Anhui, P. R. China

The certificate confirms that design plans and data of the listed products were assessed and found to comply with applicable sections of ABS Rules. The listed cable designs are accepted for installation on ABS units according to the intended service defined in the certificate attachment.

Covered Cable Types

The certificate attachment lists the following XLPE and EPR insulated shipboard power cable types with different armour, inner covering and fire performance combinations:

  • CJ86/SC, CJ96/SC, CJ85/SC, CJ95/SC series with NC variants

  • CJPJ, CJPJ85, CJPJ95, CJPJ80, CJPJ90 series with SC or NC variants

  • CJPF, CJPF86, CJPF96, CJPF80, CJPF90 series with SC or NC variants

  • CEPF, CEPF86, CEPF96, CEPF80, CEPF90 series with SC or NC variants

  • CEPJ, CEPJ85, CEPJ95, CEPJ80, CEPJ90 series with SC or NC variants

  • CEF/SA/NA series

Constructions include XLPE or EPR insulation, PO or cross-linked PO sheath, tinned copper wire braid or galvanized steel wire braid armour, with core numbers from 1 to 37 and cross sections from 1mm2 up to 240mm2 according to type.

Fire Performance Types

  • Type SA: bunched cable flame retardant, complying with IEC 60332-1 and IEC 60332-3 Category A

  • Type NA: fire resistant cable, complying with IEC 60332-1, IEC 60332-3 Category A, IEC 60331-1 and IEC 60331-2

  • Type SC: halogen free low smoke bunched flame retardant cable, complying with IEC 60332-1, IEC 60332-3 Category A, IEC 60754-1/2 and IEC 61034

  • Type NC: halogen free low smoke fire resistant cable, complying with IEC 60332-1, IEC 60332-3 Category A, IEC 60754-1/2, IEC 61034, IEC 60331-1 and IEC 60331-2

Application

This certificate applies to CJ Series and CE Series shipboard power cables used in power distribution systems on ABS classed vessels. It is used in project documentation together with the manufacturing assessment and type test reports for the specific cable types supplied.

Related Certificates

For the ABS factory qualification, see the ABS Manufacturing Assessment certificate. For product type test documents, see our DNV Type Approval TAE000050C, Nippon Kaiji Kyokai certificates and other documents on the Certifications & Test Reports page. For the related cable range, see Marine & Offshore Cables.

Certificate Download and Verification

Use the Download button on this page to get the ABS PDA certificate PDF with the full type listing attachment. The certificate remains valid until 18 November 2026, or until the applied Rules and Standards are revised or a design modification requires reassessment, whichever occurs first. Please confirm the current validity for your project with the Anhui Tiankang sales team.

FAQ

Q1: What is an ABS Product Design Assessment?

A Product Design Assessment is an ABS evaluation of the product design plans and data. It confirms the design complies with applicable ABS Rules. By itself, it does not constitute Type Approval, and unit certification procedures under ABS Rules still apply.

Q2: Which cable series are covered by certificate 21-2153557-PDA?

The certificate covers CJ Series and CE Series shipboard power cables, including XLPE insulated CJ types and EPR insulated CE types with SC, NC, SA and NA fire performance variants.

Q3: When is this certificate valid?

The certificate is effective from 19 November 2021 and expires on 18 November 2026, subject to revision of the applied Rules and Standards or design changes requiring reassessment.

Q4: What is the difference between PDA and Manufacturing Assessment?

PDA assesses the product design against ABS Rules. The Manufacturing Assessment evaluates the factory production quality system. For cable supply to ABS classed vessels, the two documents work together with type test reports for the specific cable types.

Q5: What sizes are covered?

Core numbers from 1 to 37 and nominal cross sections from 1mm2 to 240mm2 are listed, subject to the specific cable type. Please send your specification for size confirmation.

Request Verified Copy

For quotation, TDS, size confirmation or a verified certificate copy with the type listing attachment, please contact Anhui Tiankang with the cable type, standard, specification, quantity and destination port.

Need this certificate for a project?

Send the cable type, standard, project country and classification society requirement. We will confirm the applicable certificate scope.

Request Certificate Back to Certifications
Quick Inquiry

Need a full quotation? Open Request a Quote

WhatsApp

+86-18855014777

sales@tiankangmail.com

Top