DNV Type Approval Certificate TAE000050D for Anhui Tiankang CJ86/SC, CJ96/SC, CJ85/SC and CJ95/SC XLPE insulated shipboard power cables, 0.6/1kV, flame retardant, halogen free and low smoke, valid until 6 January 2030.
If the download does not open, please contact sales@tiankangmail.com for a verified copy.
Certificate Overview
This page provides the DNV Type Approval Certificate TAE000050D issued to Anhui Tiankang (Group) Shares Co., Ltd. for XLPE insulated shipboard power cables with type designation CJ86/SC, CJ96/SC, CJ85/SC and CJ95/SC.
-
Certificate number: TAE000050D
-
Rated voltage: 0.6/1kV
-
Temperature class: 90°C
-
Issued: 7 January 2025 at Hamburg
-
Valid until: 6 January 2030
-
Issued by: DNV, local unit Nanjing NB & CMC
-
DNV Job ID: 262.1-040955-1
The certificate confirms compliance with DNV rules for classification of ships, offshore units and high speed and light craft. Products covered by this certificate are accepted for installation on all vessels classed by DNV, subject to the certificate terms and project requirements.
Approved Cable Types
-
CJ85/SC
-
CJ86/SC
-
CJ95/SC
-
CJ96/SC
These are XLPE insulated shipboard power cables with tinned stranded copper conductor class 2, extruded inner covering, optional copper wire braid or galvanized steel wire braid armour, and SHF1 or SHF2 halogen free outer sheath. The SC suffix indicates flame retardant, halogen free and low smoke types.
The certificate covers single core up to 240mm2, two core, three core, four core, multi-core up to 37 cores, and earth core configurations such as 3x2.5+1x2.5, 3x16+1x16, 3x25+1x16, 3x50+1x25, 3x95+1x50, 3x150+1x95 and 3x240+1x120, with cross sections from 1mm2 to 240mm2.
Standards and Testing
The type approval documentation lists compliance with the following standards:
-
IEC 60092-350: general construction and test methods of power, control and instrumentation cables for shipboard and offshore applications
-
IEC 60092-353: power cables for rated voltages 1kV and 3kV
-
IEC 60092-360: insulating and sheathing materials for shipboard and offshore cables
-
IEC 60332-3-22 Category A: bunched cable flame retardance
-
IEC 60754-1: halogen acid gas content, low halogen
-
IEC 60754-2: acidity and conductivity, halogen free
-
IEC 60684-2 clause 45.2: low level fluorine content
-
IEC 61034-1/2: low smoke, light transmittance above 60%
The SOLAS requirements for limiting fire propagation along bunches of cables are fulfilled without additional measures. Type test reports TN24-4513E, TN24-4511E, TN24-4512E and TN24-4510E are referenced in the certificate.
Application
This certificate applies to general power distribution on ships and offshore units where DNV type approved, flame retardant, halogen free and low smoke shipboard power cables are required.
Related Certificates
For the fire resistant NSC variants of the same cable family, see DNV Type Approval TAE000050C for CJ85/NSC, CJ86/NSC, CJ95/NSC and CJ96/NSC. For the same types with PO sheath construction, see DNV Type Approval TAE000050B for CJPF86/SC and CJPJ85/SC series. For the related cable range, see Marine & Offshore Cables.
Certificate Download and Verification
Use the Download button on this page to get the DNV certificate PDF. For project submission, please confirm the cable type, size, standard and certificate validity with the Anhui Tiankang sales team before order placement.
FAQ
Q1: Which cable types are covered by DNV certificate TAE000050D?
The certificate covers CJ86/SC, CJ96/SC, CJ85/SC and CJ95/SC XLPE insulated shipboard power cables with flame retardant, halogen free and low smoke performance.
Q2: What is the difference between TAE000050D and TAE000050C?
Both certificates cover the CJ86, CJ96, CJ85 and CJ95 cable family at 0.6/1kV. TAE000050D covers the SC flame retardant types, while TAE000050C covers the NSC fire resistant types with mica tape and IEC 60331 circuit integrity testing. Please select according to whether the project requires fire resistance.
Q3: What is the rated voltage and temperature class?
The rated voltage is 0.6/1kV and the temperature class is 90°C.
Q4: When is this certificate valid?
The certificate was issued on 7 January 2025 and is valid until 6 January 2030, subject to DNV periodical assessment after 2 years and 3.5 years.
Q5: What information is needed for a quotation?
Please provide the cable type, core configuration and size, quantity or length, destination port and required delivery time.
Request Verified Copy
For quotation, TDS, size confirmation or a verified certificate copy, please contact Anhui Tiankang with the cable type, standard, specification, quantity and destination port.