RINA type approval certificate ELE005524WS for CE CJ series shipboard power cable

Certificate Overview

This page provides the Type Approval Certificate No. ELE005524WS/001 issued by RINA Services S.p.A. to Anhui Tiankang (Group) Shares Co., Ltd. for shipboard electric power cables of the CE and CJ series.

  • Certificate number: ELE005524WS/001

  • Product: Shipboard electric cables, CE and CJ series, 0.6/1kV

  • Rated voltage: 0.6/1kV

  • Temperature class: 90°C

  • Issued: 18 June 2024 at Shanghai

  • Valid until: 17 June 2029

The certificate confirms that the product complies with the applicable requirements of the RINA type approval, referencing IEC 60092-350, IEC 60092-360, IEC 60092-353, IEC 60228, IEC 60331-1, IEC 60331-21, IEC 60332-1, IEC 60332-3-22 Category A, IEC 60754-1/2 and IEC 61034-2.

Approved Cable Types and Range

The certificate covers a comprehensive range of EPR insulated CE types and XLPE insulated CJ types with flame retardant, fire resistant and halogen free variants:

  • CEF, CEFR, CEF80, CEF90 with /DA, /SA or /NA suffix

  • CEPF, CEPF80, CEPF86, CEPF90, CEPF96 and CEPJ, CEPJ80, CEPJ85, CEPJ90, CEPJ95 with /SC or /NC suffix

  • CE86, CE96, CEPFR, CEPFR80, CEPFR86, CEPFR90, CEPFR96 and CEPJR, CEPJR80, CEPJR85, CEPJR90, CEPJR95 with /SC or /NC suffix

  • CJ86, CJ96, CJ85, CJ95, CJPJ, CJPJ80, CJPJ85, CJPJ90, CJPJ95, CJPF, CJPF80, CJPF86, CJPF90, CJPF96 with /SC or /NC suffix

  • CJPJR, CJPJR80, CJPJR85, CJPJR90, CJPJR95 and CJPFR, CJPFR80, CJPFR86, CJPFR90, CJPFR96 with /SC or /NC suffix

Size coverage: 1 core from 1mm2 to 240mm2, 2 core from 1mm2 to 120mm2, 3 core with earth from 1mm2 to 240mm2, 4 to 5 core with earth from 1mm2 to 185mm2, and 6 to 37 core from 1mm2 to 4mm2, with conductor sizes up to 300mm2 per the certificate notes.

Type Designation Guide

Per the certificate enclosure, the letters used in the type designations have the following meanings: C for shipboard power cable, J for XLPE insulation, E for EPR insulation, PJ for cross-linked polyolefin and PF for thermoplastic polyolefin, F for polychloroprene rubber, 8 for copper or tinned copper wire braid armour, 9 for galvanized steel wire braid armour, 5 for cross-linked polyolefin outer sheath and 6 for thermoplastic polyolefin outer sheath. Flammability codes: DA for single cable flame retardant, SA for bunched flame retardant, NA or NSA for bunched flame retardant with fire resistance, SC for bunched flame retardant low smoke halogen free, and NC or NSC for bunched flame retardant fire resistant low smoke halogen free.

Testing and Documentation

Type testing is documented through China National Centre for Quality Supervision and Test of Electric Wire and Cable reports CT16-3471-1/2/3/4, CT12-2618-2/6/7 and CT12-4877-3, and Shanghai Intelligent Service and Technology reports TN24-1612E, TN24-1613E and TN24-1614E. An asbestos-free declaration and routine test reports signed by the attending surveyor are filed with RINA.

Application and Notes

  • Applies to 0.6/1kV shipboard electric power cables on vessels classed by RINA

  • Type approval certifies that a representative sample meets the applicable design criteria

  • Any modification or change requires RINA approval before being valid

  • Manufacturing sites declared to RINA: Tianchang main plant and the Chuzhou High-tech Industrial Development Zone facility

Related Certificates

For the companion RINA certificates, see ELE005524WS/002 for 150/250V shipboard control cables and ELE005524WS/003 for shipboard communication cables. For the same cable families under Bureau Veritas, see BV Type Approval 54112/B0 BV. Under DNV, see TAE000050C for NSC types, TAE000050D for SC types and TAE000050B. Under Nippon Kaiji Kyokai, see NK TA24282M. For the applicable power cable standard, see our IEC 60092-353 guide, and for fire performance differences see the fire resistant vs flame retardant comparison.

Certificate Download and Verification

Use the Download button on this page to get the RINA certificate PDF with the full enclosure. For RINA classed projects, please confirm the applicable cable types and documentation with the Anhui Tiankang sales team before order placement.

FAQ

Q1: Which cable types are covered by RINA certificate ELE005524WS?

The certificate covers CE and CJ series 0.6/1kV shipboard power cables across DA, SA, NA, SC and NC variants, from 1 core to 37 cores and 1mm2 up to 300mm2.

Q2: When is this certificate valid?

The certificate was issued on 18 June 2024 and is valid until 17 June 2029.

Q3: What is the difference between NA and NC types?

NA is bunched flame retardant with fire resistance; NC adds low smoke halogen free performance to the same fire resistant construction.

Q4: Are both manufacturing sites covered?

Yes, the certificate declares both the Tianchang main plant and the Chuzhou High-tech Industrial Development Zone facility to RINA.

Q5: What information is needed for a quotation?

Please send the cable type with suffix, core configuration and size, quantity or length, destination port and whether the project is RINA classed.

Request Verified Copy

For quotation, TDS, type confirmation or a verified certificate copy, please contact Anhui Tiankang with the cable type, suffix, specification, quantity, destination port and class society requirement.

Need this certificate for a project?

Send the cable type, standard, project country and classification society requirement. We will confirm the applicable certificate scope.

Request Certificate Back to Certifications
Quick Inquiry

Need a full quotation? Open Request a Quote

WhatsApp

+86-18855014777

sales@tiankangmail.com

Top